Product information "230 Volt Safety Transformer. 32 VA"

Model

Track voltage adjustable between 4 and 16 V. Lighting voltage 16 V. Plastic housing. Dimensions 120 x 140 x 80 mm. On/off switch on the mains cable. VDE approved. The 32 VA safety transformer is suitable only for enclosed rooms.

Note

Tested safety. We guarantee the flawless operation of our trains only with original Märklin transformers. The transformers must be protected against moisture and are not approved for outdoor operation. Connect to AC only. Please also observe the operating instructions for the units. Multi-train operation with separate circuits. If several trains are to be operated independently of one another in conventional running, the layout is divided into several circuits. A transformer and at least one feeder track are assigned to each circuit, which is simply separated electrically from the other circuits by a centre conductor insulation (74030, 5022 or 7522). In the Märklin H0 system the rails are at the same potential everywhere and do not have to be interrupted. Circuits can be closed routes such as most main lines, but also other track sections with independent operation. Branch lines, station areas, sidings, shunting areas or locomotive depots lend themselves to this. This also makes it possible to control additional locomotives individually at the same time as fully automatic operation on the line. The catenary of electrified sections of line is as a rule also connected to its own transformer as an additional circuit in each case. This even allows the locomotives used in catenary operation to be controlled independently of the vehicles supplied via the centre conductor. Several catenary circuits are to be separated by the 7022 insulating contact wire section. Power consumption of locomotives and accessories. The output power indicated on the transformer (in VA) is available for the power consumption of all loads in the circuit. Here are some sample calculations: under load, smaller locomotives (e.g. tank locomotive 30001 or similar) require about 9 VA, larger locomotives (e.g. diesel locomotive 33803) about 12 VA. The power consumption of the train lighting depends on the light bulbs installed and is usually below 2 VA per coach. After deducting the power required at the track, the remaining reserve of the transformer can be used at the lighting output for electrical accessories. Here light bulbs consume between 0.5 and 1 VA (see the table "Light bulbs for accessories") and point or signal motors about 6 VA when switching. Further electrical accessories are to be connected to additional lighting transformers. The 66471 safety transformer is not a children's toy.

The model

Scale H0
Catalogue no. 66471
Minimum age 15 years

Identification

Barcode 4001883664712

Safety notices

For adults only.

WEEE no.: DE30519521