Accessories
Item no. 61040 Plug-in set, replacement for Intellibox 650, 65000, 65050, Power 3 (until end of Sept. 2003), TwinCenter
On order, lead time to be confirmed
Item no. 61065 plug-in set, replacement for Intellibox 3 and Intellibox 2neo
On order, lead time to be confirmed
Until now, our LocoNet cables have been supplied with plug/plug or socket/socket connectors in a crossed configuration. This means that Pin 1 was connected to 6, Pin 2 to 5, and so on. From now on, they will be available in an uncrossed (1:1) configuration, meaning Pin 1 is connected to 1, Pin 2 to 2, and so on.
On order, lead time to be confirmed
Until now, our LocoNet cables have been supplied with plug/plug or socket/socket connectors in a crossed configuration. This means that Pin 1 was connected to 6, Pin 2 to 5, and so on. From now on, they will be available in an uncrossed (1:1) configuration, meaning Pin 1 is connected to 1, Pin 2 to 2, and so on.
On order, lead time to be confirmed
Loco-Net coiled cable. Please note that the length stated refers to the maximum length when stretched out. Depending on the delivery batch, this length can vary between 2.5 m and 3 m. Important note! Until now our LocoNet cables with plug/plug or socket/socket have been supplied in crossed form. That means: until now pin 1 was connected to 6, pin 2 to 5 and so on. In future they will be available in uncrossed (1:1) form, so pin 1 is connected to 1, pin 2 to 2 and so on. This has become necessary because of a new booster concept. These cables will replace the old cable version. Only when several Power 2 boosters are to be connected to one another via LocoNet are the existing crossed versions of the cables required. All other devices supplied until now (except Power 2) can be connected to one another with both types of cable. Nothing changes for branches and distributors, as these have always been supplied in uncrossed form.
On order, lead time to be confirmed
Until now, our LocoNet cables have been supplied with plug/plug or socket/socket connectors in a crossed configuration. This means that Pin 1 was connected to 6, Pin 2 to 5, and so on. From now on, they will be available in an uncrossed (1:1) configuration, meaning Pin 1 is connected to 1, Pin 2 to 2, and so on.
On order, lead time to be confirmed
Until now, our LocoNet cables have been supplied with plug/plug or socket/socket connectors in a crossed configuration. This means that Pin 1 was connected to 6, Pin 2 to 5, and so on. From now on, they will be available in an uncrossed (1:1) configuration, meaning Pin 1 is connected to 1, Pin 2 to 2, and so on.
On order, lead time to be confirmed
Until now, our LocoNet cables have been supplied with plug/plug or socket/socket connectors in a crossed configuration. This means that Pin 1 was connected to 6, Pin 2 to 5, and so on. From now on, they will be available in an uncrossed (1:1) configuration, meaning Pin 1 is connected to 1, Pin 2 to 2, and so on.
On order, lead time to be confirmed
Until now, our LocoNet cables have been supplied with plug/plug or socket/socket connectors in a crossed configuration. This means that Pin 1 was connected to Pin 6, Pin 2 to Pin 5, and so on. From now on, they will be available in an uncrossed (1:1) configuration, meaning Pin 1 is connected to Pin 1, Pin 2 to Pin 2, and so on.
On order, lead time to be confirmed
Until now, our LocoNet cables have been supplied with plug/plug or socket/socket connectors in a crossed configuration. This means that Pin 1 was connected to 6, Pin 2 to 5, and so on. From now on, they will be available in an uncrossed (1:1) configuration, meaning Pin 1 is connected to 1, Pin 2 to 2, and so on.
On order, lead time to be confirmed
Four in one – distributor, patch panel, power feed, load indicator The LocoNet distributor offers you 6 LocoNet connections. You can screw it under your layout or integrate it into the layout frame with the front plate supplied. The LocoNet distributor works as a LocoNet power feed when the additional plug-in power supply 20206 is plugged in. Another 630 mA is then available at 3 LocoNet sockets of the distributor for the LocoNet T. The other connections remain LocoNet B or T, depending on which LocoNet output of the command station the distributor is connected to. Dimensions 70 x 40 mm, front plate 90 x35 mm Art. no. 62261 LocoNet distributor
On order, lead time to be confirmed
Luisa – LocoNet universal isolator, power supply and indicator. Luisa is a LocoNet repeater, galvanic isolator, power feed and distribution unit in one device: it generates a new galvanically isolated LocoNet branch via optocouplers, refreshes the signals and supplies power to the connected devices (12 V, total max. 500 mA). In the event of a short circuit in the second branch, the LocoNet in the primary branch remains fully operational. The integrated RS amplifier provides the signals for operating boosters on the LocoNet B branch. Multi-colour LEDs indicate LocoNet input and output, RS signal and load. Connections: LocoNet input, galvanically isolated LocoNet output (max. 50 mA), three LocoNet T sockets with power feed, DC socket for the supplied 12 V switched-mode power supply. This allows all Uhlenbrock LocoNet devices such as feedback modules and LocoNet boosters to be connected to LocoNet-capable central units with a non-common-return output stage (e.g. Roco Z21, Tams mc² MasterControl 2, KM1 System Control 9, DigiKeijs DR5000, YaMoRC Command Station, Viessmann Commander 2). Front panel 90 x 35 mm.
On order, lead time to be confirmed
The LocoNet interface is suitable for all LocoNet digital command stations without a computer connection, such as the DAISY or the Märklin Control Unit with the 6021 infrared and LocoNet adapter. The interface is connected to a USB port on a computer. It is ideal for automatic layout control.
On order, lead time to be confirmed
The LocoNet interface is compatible with all LocoNet digital command stations without a computer connection, such as the DAISY or the Märklin Control Unit with the 6021 infrared and LocoNet adapter. The interface is connected to a USB port on a computer. It is ideally suited for automatic layout control.
On order, lead time to be confirmed
The new generation of boosters On model railway layouts with a lot of running, the command station's output is soon used up. To run a larger number of vehicles, a booster is needed. The new-generation boosters are powered by switched-mode power supplies, which are included in the delivery. The LocoNet-capable boosters Power 22, Power 40 and Power 70 are powerful multi-protocol boosters. Multi-protocol means that they can be used in 2-rail and 3-rail operation for the data formats DCC, Motorola, mfx, Selectrix and FMZ. If the boosters are operated with an Intellibox II, any error messages are shown in plain text on the Intellibox display. The features of all boosters Multi-protocol booster for the data formats DCC, Märklin-Motorola, mfx, Selectrix and FMZ Switchable to DCC braking generator mode LocoNet-capable, and therefore particularly suitable for modular layouts You can operate up to seven reversing loops, each connected to a reversing loop relay. In DCC systems, they can also be used as a braking generator. Depending on the preset deceleration of the decoders used, the locomotives brake true to prototype in stopping zones. You can connect as many braking sections as you like. With output for reversing loop relay RailCom support Short-circuit-proof, overload-proof Settings via LocoNet CVs Compatible with the ABC braking system The inexpensive 2.2 A booster for N, TT and H0 gauge Compatible with all LocoNet command stations, particularly suitable for DAISY II and Piko SmartControl light Maximum output current: 2.2 A LocoNet B connection Settings via LocoNet CVs Output voltage 15 V
On order, lead time to be confirmed
The new generation of boosters On model railway layouts with a lot of running, the command station's output is soon used up. To run a larger number of vehicles, a booster is needed. The new-generation boosters are powered by switched-mode power supplies, which are included in the delivery. The LocoNet-capable boosters Power 22, Power 40 and Power 70 are powerful multi-protocol boosters. Multi-protocol means that they can be used in 2-rail and 3-rail operation for the data formats DCC, Motorola, mfx, Selectrix and FMZ. If the boosters are operated with an Intellibox II, any error messages are shown in plain text on the Intellibox display. The features of all boosters Multi-protocol booster for the data formats DCC, Märklin-Motorola, mfx, Selectrix and FMZ Switchable to DCC braking generator mode LocoNet-capable, and therefore particularly suitable for modular layouts You can operate up to seven reversing loops, each connected to a reversing loop relay. In DCC systems, they can also be used as a braking generator. Depending on the preset deceleration of the decoders used, the locomotives brake true to prototype in stopping zones. You can connect as many braking sections as you like. With output for reversing loop relay RailCom support Short-circuit-proof, overload-proof Settings via LocoNet CVs Compatible with the ABC braking system The universal 3.5 A booster for Z, N, TT, H0 and 0 gauge Compatible with command stations from Uhlenbrock, Märklin, Fleischmann, Piko, KM1, Lenz, ESU, Viessmann and many others Selectable output voltage Maximum output current: 3.5 A Connections: LocoNet B, DCC booster (CDE), Märklin booster Settings via switches and via LocoNet CV programming The output voltage can be selected on the switched-mode power supply. 17 V for H0 3-rail (Märklin) and 0 gauge 15 V for N, TT, H0 gauge 11 V for Z gauge
On order, lead time to be confirmed
The new generation of boosters On model railway layouts with a lot of running, the command station's output is soon used up. To run a larger number of vehicles, a booster is needed. The new-generation boosters are powered by switched-mode power supplies, which are included in the delivery. The LocoNet-capable boosters Power 22, Power 40 and Power 70 are powerful multi-protocol boosters. Multi-protocol means that they can be used in 2-rail and 3-rail operation for the data formats DCC, Motorola, mfx, Selectrix and FMZ. If the boosters are operated with an Intellibox II, any error messages are shown in plain text on the Intellibox display. The features of all boosters Multi-protocol booster for the data formats DCC, Märklin-Motorola, mfx, Selectrix and FMZ Switchable to DCC braking generator mode LocoNet-capable, and therefore particularly suitable for modular layouts You can operate up to seven reversing loops, each connected to a reversing loop relay. In DCC systems, they can also be used as a braking generator. Depending on the preset deceleration of the decoders used, the locomotives brake true to prototype in stopping zones. You can connect as many braking sections as you like. With output for reversing loop relay RailCom support Short-circuit-proof, overload-proof Settings via LocoNet CVs Compatible with the ABC braking system The powerful 6.8 A booster for 0, I and IIm (G) gauge Compatible with command stations from Uhlenbrock, Märklin, Fleischmann, Piko, KM1, Lenz, ESU, Viessmann and many others Selectable output voltage Maximum output current: 6.8 A Connections: LocoNet B, DCC booster (CDE), Märklin booster Settings via switches and via LocoNet CV programming The output voltage 16 V, 18 V or 22 V can be selected on the switched-mode power supplies. 17 V for H0 3-rail (Märklin) and 0 gauge 15 V for N, TT, H0 gauge 11 V for Z gauge
On order, lead time to be confirmed
The function of feedback modules Feedback modules pass on the information from the track occupancy detector, indicating whether a vehicle is present in the track sections they monitor, to the connected devices (e.g. IB-Switch) or to a computer control program. These automatically execute the switching command that has been stored for this feedback. This may involve switching a single solenoid accessory or an entire route. The 2-rail feedback modules consist of an occupancy detector, a feedback unit and a voltage monitor. The occupancy detectors monitor the track inputs. The current monitor registers any current flow in the isolated section that is greater than 3 mA. This detects locomotives, illuminated coaches and conductive axles. The voltage monitor prevents an erroneous "clear" message from being given when the power is switched off. The 3-rail version works with an isolated and separated rail side, which is connected to the detector module and is connected to ground via the conductive axles of the vehicles. The feedback module reports every change of state, "clear" or "occupied", via LocoNet to the command station and to other LocoNet devices. In contrast to other bus systems, LocoNet is extremely reliable and dependable for transmitting information such as feedback messages. The address is set via a programming button, via the programming menu of the Intellibox or, very conveniently, via the LocoNet-Tool software.
On order, lead time to be confirmed
The function of feedback modules Feedback modules pass on the information from the track occupancy detector, indicating whether a vehicle is present in the track sections they monitor, to the connected devices (e.g. IB-Switch) or to a computer control program. These automatically execute the switching command that has been stored for this feedback. This may involve switching a single solenoid accessory or an entire route. The 2-rail feedback modules consist of an occupancy detector, a feedback unit and a voltage monitor. The occupancy detectors monitor the track inputs. The current monitor registers any current flow in the isolated section that is greater than 3 mA. This detects locomotives, illuminated coaches and conductive axles. The voltage monitor prevents an erroneous "clear" message from being given when the power is switched off. The 3-rail version works with an isolated and separated rail side, which is connected to the detector module and is connected to ground via the conductive axles of the vehicles. The feedback module reports every change of state, "clear" or "occupied", via LocoNet to the command station and to other LocoNet devices. In contrast to other bus systems, LocoNet is extremely reliable and dependable for transmitting information such as feedback messages. The address is set via a programming button, via the programming menu of the Intellibox or, very conveniently, via the LocoNet-Tool software.
On order, lead time to be confirmed
The inexpensive replacement for solenoid accessory and switching decoders, with outstanding capabilities The LocoNet switching module is a switching and solenoid accessory decoder with a LocoNet connection and switches up to ten points or colour light signals, including multi-aspect ones with slow fade-in and fade-out, or up to 20 lights on your layout. And all of this mixed on a single module. Our LocoNet switching module is a true all-rounder. A single module with which you carry out all the switching operations on your layout. With the switching module you can switch lighting, points, uncoupling tracks, semaphore signals, colour light signals, effect lighting and St Andrew's crosses. All these switching tasks can be distributed as you wish across the 20 switching outputs. We have placed particular emphasis on prototypical control of colour light signals. The switching module switches main signals and distant signals with up to 4 aspects. And the clever part of the signal control is the cross-fade function. The change of light takes place, if you wish, not abruptly but with a smooth cross-fade from one signal aspect to the other. St Andrew's crosses and other effect lighting are no problem either. With a flasher generator and the cross-fade function you can create a prototypical level crossing cross. Or combine both flasher generators to make a switchable faulty street lamp. With the module's 20 switching outputs you can operate up to ten points, five multi-aspect signals or 20 switching functions. Each output can be loaded with up to 1 A, but the total load must not exceed 3 A. The LocoNet switching module is supplied with power by a separate transformer and does not load the LocoNet or the digital command station. Art. no. 63410 LocoNet switching module
On order, lead time to be confirmed
The LocoNet switching module (63410) has a common positive terminal for all consumers. Connecting two motorised point motors or colour light signals with a common negative terminal is not possible. Motorised point motors require an operating voltage with alternating polarity.
On order, lead time to be confirmed
The LocoNet analogue switching module is a variant of our LocoNet switching module. An analogue switching module can be configured for: 10 points and 2 handle-operated semaphore signals (momentary contact), 10 colour light signals (maintained contact), 20 switching outputs. Up to 20 analogue switching modules can be operated on one Track-Control.
On order, lead time to be confirmed
4 adjustable holding positions and rotational speed; 4 holding positions per servo switchable via 2 addresses. Switching outputs for lighting, colour and semaphore signals, points, St Andrew's crosses or common crossing polarisation with additional relay. Each output can be configured as a continuous or momentary output.
On order, lead time to be confirmed
It is now possible to connect LocoNet to your computer network or to control the model railway layout directly using your mobile phone or tablet via Wi-Fi.
On order, lead time to be confirmed